High quality transformer core cutting line supplier
Top rated core slitting machine manufacturer: Why should the iron core of the transformer be grounded? Transformer core grounding is for safety and electromagnetic compatibility considerations. On the one hand, grounding the transformer core prevents contact voltages caused by ground faults, which can pose a shock hazard to humans. Because when a ground fault occurs on one side of the transformer, the iron core on the other side may have a voltage in contact with the earth. If it is not grounded, this voltage cannot be released. On the other hand, grounding the transformer core can also reduce electromagnetic radiation interference, especially for radio equipment and communication systems. This is because the current will generate a magnetic field in the iron core. If the iron core is not grounded, this magnetic field may leak into the surrounding environment and interfere with the normal operation of other equipment. In conclusion, grounding the transformer core is a protective measure against shock hazards and electromagnetic interference. Find additional info at https://www.canwindg.com/products-20763.
Why does the current source inverter need a larger transformer capacity? Current source inverter is a common type of inverter. Its control method adopts current loop control, which has the advantages of high precision and strong adaptability, and is widely used in industrial production. Due to the working characteristics of the current source inverter, a large transformer capacity is required for the following reasons: The current source inverter adopts the intermediate inductance: the current source inverter adopts the intermediate inductor, which can realize the phase difference between the output voltage and the current, so as to realize the frequency conversion control. However, since the intermediate inductor needs to withstand large current and voltage, it is necessary to select a transformer with a larger capacity to ensure the normal operation of the inductor.
When these harmonic currents flow through a transformer, they can cause increased core losses due to hysteresis and eddy currents. Hysteresis loss is related to the magnetization and demagnetization of the transformer’s core material in response to the alternating current. Eddy current loss occurs when induced currents circulate within the core material, creating local magnetic fields that oppose the main field. Both these losses increase with the frequency of the current. Thus, higher frequency harmonic currents can lead to considerably higher core losses, reducing the transformer’s efficiency and causing it to overheat, which can shorten its lifespan.
Canwin is a professional ctl line manufacturers & suppliers china, we have been specialized in ctl machines for over 20 years.This cut to length production line adopts advanced control system to ensure the accurate and stable operation of the cut to length production line. Embedded operating terminal can complete parameter setting quickly and conveniently. After the coil material of silicon steel sheet is punched and cut into certain shape and size by this cut to length production line, the classification and finishing work is completed at the end of the production line, and it is automatically stacked into 20 columns and used for the core assembly.
The trademark “CANWIN” has won the title of the famous trademark of the international electrotechnical association and the trademark CANWIN CNC” has been recognized as a high -end manufacturing brand in China. We has been judged as Guangdong province enterprise that strictly contracts and keeps promises” and won the honor of”excellent supplier of Chinese electrical equipment” successively. The company has a number of national patents, and won the Guangdong provincial department of science and technology major project award the first set of domestic new products award; The company is a key enterprise in the field of electric power electrical equipment manufacturing in China, and a core professional equipment supplier of state grid, China southern power grid and many listed companies in the electric power industry. Its products are exported to countries and regions in Asia, Africa, Latin America, Europe and the United States.
Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.
Box transformer (usually referred to as “box transformer”) is a compact complete set of power distribution equipment composed of high-voltage power equipment, power transformer, low-voltage electrical equipment and auxiliary equipment. Canwin, a professional box transformer manufacturer & supplier, which focuses on the substation type transformer and traditional box type transformer design in the box shell, A box type transformer is an electronic device that transforms power into alternating current for the purpose of transferring power from one point to another.With small volume, light weight, low noise, low loss, high reliability. Transformer box is widely used in residential areas, commercial centers, light stations, airports, factories and mines, enterprises, hospitals, schools and other places.
The transformer core provides a magnetic path to channel flux. The use of highly permeable material (which describes the material’s ability to carry flux), as well as better core construction techniques, helps provide a desirable, low reluctance flux path and confine lines of flux to the core. An electrical distribution cabinet is a part of an electrical system whose task is to distribute electrical energy. It includes distribution, protection, measurement, control and signaling instruments. The electrical distribution box also contains wires, various types of insulation, and support components. Discover even more details at https://www.canwindg.com/
Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.
Energy management system, which uniformly allocates and manages the wind energy, photovoltaic, power grid, battery system and distribution system of micro grid, so as to achieve energy efficiency and high-quality energy allocation. The remote cloud platform and mobile terminal can optimize the system through big data analysis, while reversing the relevant information and operation status to the users’ mobile phone. Containerized Energy Storage System is a complete, self-contained battery solution for a large-scale marine energy storage. The batteries and converters, transformer, controls, cooling and auxiliary equipment are pre-assembled in the self-contained unit. Advantages of containerized power systems: customization, scalability, stackable and cost effective.
Impedance voltage (%): Short-circuit the secondary winding of the transformer and slowly increase the voltage on the primary winding. When the short-circuit current of the secondary winding equals the rated value, the voltage applied on the primary side is the impedance voltage. It is usually expressed as a percentage of the rated voltage. Phase number and frequency: Three-phase is represented by S, and single-phase is represented by D. The frequency f of China’s national standard is 50Hz.There are countries abroad with 60Hz (such as the United States).I. Temperature rise and cooling: The difference between the temperature of the transformer winding or upper oil layer and the temperature of the surrounding environment is called the temperature rise of the winding or upper oil layer. The limit value of the temperature rise of the oil-immersed transformer winding is 65K, and the temperature rise of the oil surface is 55K.There are also various cooling methods: oil-immersed self-cooling, forced air cooling, water cooling, tube type, sheet type, etc.