Premium flow meter measuring devices factory: In this paper, there are three situations that lead to the radar level meter measurement value jump, respectively, closed metal cover, condensation on the antenna, power supply power supply is insufficient. In fact, the radar level meter measurement value jump belongs to a relatively common problem, leading to the emergence of this problem for a number of reasons, the emergence of problems in a timely manner to find the cause and solve the problem is the most important. Liquid level is the height of the liquid level in a sealed container (pool) or an open container (pool). In addition, liquid level measurement is divided into two categories: continuous measurement and level measurement. Find even more information at flow instrumentation.

With the continuous advancement of science and technology, radar water level meters have been used more and more. It has the advantages of low cost, high stability, flexibility, high reliability, low power consumption, convenient parameter setting, safe and simple maintenance, etc., and has important promotion value. Today, the editor will take you to a simple understanding of radar water level meter. Radar water level meter is a kind of measurement equipment introduced from abroad in recent years. The water level meter has mature technology, high measurement accuracy, easy installation, and is not restricted by environment and geography, so it has been widely used.

An important part of steam generation is the quality of the steam generated. Maintaining water quality in the boiler within design parameters ensures the highest quality steam possible while minimizing blowdown of the boiler, both of which improve energy and resource management. Continuous or manual blowdown of the boiler minimizes scale accumulation and corrosion resulting from impurities in the water. The blowdown provides a means of accommodating liquid and impurities from the boiler, with the latter facilitating energy recovery through the use of flash steam.

Unveiling the Benefits – The popularity of radar level measurement has significantly increased due to its range of advantages. Let’s explore these benefits, which have solidified radar’s position as the choice in industries- Accurate and Non-Contact Measurement- One of the key attractions of radar level measurement is its non-contact approach. Unlike methods that require interaction between sensors and materials radar sensors use electromagnetic waves to measure levels and capture reflected signals. This contactless method minimizes the sensor tear, leading to greater lifespans and reduced maintenance costs.

KAIDI level transmitter manufacturer is dedicated in providing complete customized solutions for a wide range of industrial automation process applications – in material level, liquid flow, pressure and temperature. We are constantly developing and innovating, our core vision – “to provide solutions that exceed customers’ expectations. In 2012, the company successfully expanded its operations both locally and internationally, achieving global success and recognition for quality fork type level switch, magnetic level gauge products and services. Discover even more details on https://www.kaidi86.com/. Suitable for chemical industry, petroleum industry, metallurgical industry, water conservancy and electronic industry, etc.

Humidity interference, when the humidity increases, it will cause the insulator resistance to decrease, the dielectric constant to increase, the skeleton to be fluffy, and the resistance to increase, resulting in an increase in leakage current and changes in capacitance and inductance. Also, it softens the colloid and reduces measurement accuracy. Chemical interference, chemical interference usually refers to some corrosive gases, such as acids and alkalis. The long-term action of these gases will not only damage the instrument and internal components, but also conduct electricity with the metal, affecting the normal operation of the radar level transmitter.

Application conditions, application conditions generally include calm liquid level, slightly fluctuating surface, turbulent surface, with stirring, with foam and so on. The more complex the conditions, the more interference echoes, and the smaller the actual measured range. In a complex environment, a precision radar with strong ability to deal with interference echoes or an antenna with a larger size should be selected.

In the process of cement production, material level detection and material level alarm control play an important role from mining and crushing to storage and packing of finished cement. But because of the complex working conditions of cement plant, radar level meter has no small difficulty in measuring. Today, I would like to talk with you about specific difficulties and solutions. First cement plant material for measurement in the dust under the condition of particularly large, especially some pneumatic feed bin, involves the kinds of materials, material particle size is differ, dielectric constant is different also, such as broken limestone, raw meal, clinker, fly ash, coal, cement, the level of the bunker, it is very difficult to accurately measure Especially fly ash bin with low dielectric constant.

The installation of the liquid level gauge should be away from the inlet, outlet, eddy current or protrusions on the inner wall to avoid the interference of electromagnetic waves and affect the measurement. When installing the guided wave radar, make sure that the diameter of the short pipe at the flange connection is greater than the height of the short pipe, otherwise the cable will contact the short pipe wall due to shaking, and the liquid level cannot be measured accurately. How to choose a model, in the final analysis, you still need to understand your own working conditions and the characteristics of different instruments, and judge whether the two match, so that you can get twice the result with half the effort.Want to know about ultrasonic flow meter advantages and disadvantages, click here.

Product features: Large display range, wide range of use, suitable for low temperature, medium temperature, high pressure occasions. It can be matched with remote transmitter output 4-20MADC standard signal to realize remote display of liquid level guage. It can also be matched with liquid level switch to realize liquid level control. Generally speaking, the material level feedback is inaccurate and untimely, which is very prone to explosion events, and there is a greater safety risk. Therefore, the requirements for the radar level meter are very high, but the radar level meter often has abnormal material level jumps or falls, or even crashes, resulting in large errors in material level measurement, which brings trouble to production and sales.