Human machine interface wholesale provider in China: Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects. See more details at hmi touch screen.

Corresponding Functional Requirements: Gemerally, small plc have functions such as logic operation, timing and counting, which can be met for equipment that only needs to be controlled by switching quantity. For systems with switching control as the main and a small number of analog control, an enhanced plc with A/D and D/A conversion units and functions of addition and subtraction arithmetic operations and data transmission can be selected. For complex control, it is required to realized PID calculation, closed-loop control, communication networking and other functions, visual control scale and complexity, and choose mid-range or high-grade plc. However, medium and large PLC are more expensive and are generally used in large-scale process control and distributed control system.

Frequency principle: That is, according to the frequency of dialogue interaction of the management object design the human-machine interface hierarchical order and dialogue window display position of the list, etc., to improve the frequency of monitoring and access to dialogue. Importance principle: That is, in accordance with the importance of management objects in the control system and the global level, the design of the human-machine interface of the main and secondary menus and the location and prominence of the dialogue window, which helps managers to grasp the importance of the control system, the implementation of good control of the sequence of decisions to achieve optimal scheduling and management.

Wuxi Mochuan Drives Technology Co.,Ltd is one manufacturer and system solution company. To quickly match the high advantage competitive model through industry experience and solution to bring a high value market and a new growth point for our customers. We mainly provide  Hmi Panel, Hmi Touch Screen , Plc Controller and permanent magnet motor. To explore more equipment value for equipment manufacturers and end users, improve efficiency, reduce costs, optimize management, and promote equipment manufacturers’ service transformation. See more details on https://www.mochuan-drives.com/.

Why touch panel interface always fail to communicate with PLC? Common reasons why touchscreens do not communicate with PLCs 1. whether the correct communication protocol is selected (Modbus, Profibus, CANopen, etherCAT) 2. Is the communication line normal (RS232 rxd TXD GND RS485 a+B-CANopen CAN_L CAN_H CAN_GND ether cat network cable) 3. Whether the communication parameters are correct (station number, baud rate, parity bits) 4. Whether there is interference The program determines that the communication between HMI operator interface and plc has fialed

This type touchscreen panel support 7inch, 9.7inch, 17inch, 22inch and 32inch, is enough to select suitable model for the project from application and cost. There are two operating temperature -10°C to 60°C and -20°C to 70°C. And all the size and model is to support ethernet, 2pcs rs485 or 2pcs rs232 is in optional. Adpoting industrial grade high quality components, high protection level design, comprehensive three-proof coating, no matter the wet underground mine, high temperature gobi or corrosive gas, oil mist or dust factory environment, can easily cope with, easy to handle.

The plastic enconomic resistive HMI panel is very high advantage competitive series. There are multiple parameter, resolution, serial port to select for user to achieve real matching per project budget for one size. But it does not mean, this type HMI touch panel performance, resolution…etc is not in perfect but more flexible. For example, there are 800×480, 1024×600 resolution, ethernet, 2xRS485, 2xRS232, RS422 are in optional for 7inch touchscreen HMI.

Selecting HMI screen hardware parameters, mainly look at the CPU running speed and the capacity of the memory. According to the project involves the amount of data exchange animation, the size of the pictures to choose the CPU and memory. When processing more data and picture format is large, needing to choose a fast running speed, memory slightly large HMI. For example, Mochuan 15.6Inch MC-H156E, 7Inch MC-H070CWE, MC-H070CW with 1GHz CortexTM-A7 in CPU. And 10.1Inch MC-H100C, MC-H100CWE with 1GHz cortexTM-A7 and 4GB Flash memory. In addition, also needing to consider the functional requirements needed in the project, such as, how to achieve the multi-level tital pop-up, whether the screen display meets the customer’s need…etc.

Industrial grade fully enclosed embedded industrial hmi touch panel can perfectly cope with all kinds of harsh environment, but also can bring more convenient management services: According to the big data collected by the embedded industrial touch screen plus simple plc, the efficiency of each equipment in the electrical room can be monitored, so that the operation level of the electrical room can be improved and improved based on the evidence.

Specifically, the two-way communication between the HCI user and the machine containing the computer, in a certain symbol and actions to achieve, such as hitting keys, moving the mouse, displaying symbols/graphics on the screen, etc. This process includes several sub-processes: identifying the interactive object – understanding the interactive object – grasping the object situation – information adaptation and feedback, etc.; and the human-machine interface is the communication media or means between the user and the machine system containing the computer, which is the software and hardware supporting the two-way information interaction between human and machine. Here the interface is defined as the media or means of communication, and its physical embodiment is the relevant supporting software and hardware, such as a graphic display terminal with a mouse, etc.